Electromagnetic shielded testing and operations facilities.
Finex EMI/EMC shelters provide specialised, fully-shielded facilities for testing, development and operations of sensitive defence electronics and communications systems. They offer comprehensive electromagnetic isolation, enabling military-grade equipment development, qualification testing and secure operations in electromagnetically complex environments.
The shielding is the product. Multi-layer Faraday cage construction with continuous mesh and double-layer walls, multi-point grounding, RF-filtered bulkhead connectors on every penetration, and pyramidal absorber treatment inside the chamber so a measurement reflects the equipment rather than the room.
Faraday Cage Build
Anechoic Treatment
RF-Filtered Penetrations
Precision Climate
What we make
What we manufacture and deliver.
Any one of these can be contracted on its own, or the whole interior delivered under a single award against one drawing set and one schedule. Everything listed is manufactured, supplied and installed by us — not sub-let after award.
Test & Qualification
Susceptibility, emissions and acceptance testing in a controlled RF environment.
Military equipment testing — EMI susceptibility and emissions testing for defence systems.
Qualification testing — system acceptance in a controlled RF environment.
Research and development for defence industry and academic electronics work.
Secure & Signal Operations
Classified development, secure operations and electronic warfare work.
Secure communications — facilities for classified system development.
Signal intelligence — secure operations and threat assessment environments.
Electronic warfare — EW system testing and counter-measure development.
RF Measurement & Expansion
Measurement chambers, satellite links, and how the facility grows.
Radar development — RF measurement chambers for design validation.
Satellite communications — uplink and downlink testing with interference verification.
Multiple isolated chambers for concurrent operations, with modular expansion.
Integrated instrumentation, remote control and automated test sequences.
Standards & compliance
Built to the standards this work is inspected against.
Wording here is deliberate: we design and manufacture to these criteria.
ElectromagneticMIL-STD-461G — electromagnetic emission and susceptibility.
SecurityTEMPEST — electromagnetic security for classified operations.
CompatibilityIEC 61000 series — electromagnetic compatibility.
Shieldingmulti-layer Faraday cage with continuous mesh and double-layer walls.
PenetrationsRF-filtered bulkhead connectors and waveguides on all external connections.
Certificationthe standards above are the design and build basis for these units. Third-party test certification is agreed and confirmed per contract before supply — ask us for the current position on any standard you intend to specify, and you will get a straight answer rather than a brochure claim.
Certificates held
Not what we design to — what we are audited for.
The certificates from our register that apply to this work, each with its issuing body and certificate number. Nothing here is a claim we have not been audited for.
Certificates held Not what we design to — what we are audited and licensed for, with the certificate number on each.
More than 1,00,000 sq. ft. across two units near Nashik. The container modification, the structural welding, the fit-out and the finishing stay under our control instead of being sub-let after award.
02
Standard logistics platforms
Built on ISO container platforms, so a unit moves on the truck, rail and airlift chains a force already operates — no special handling equipment to procure alongside it.
03
One contract to handover
Structure, shielding, power, climate control and interior fit-out on a single order, with one schedule and one name on the handover certificate.
04
Straight answers on compliance
We will tell you what is certified, what is built to a standard and what still needs testing, before you specify it. An awkward conversation early is cheaper than a rejected inspection.
FAQ
Questions we get on this scope.
If yours is not here, ask — we would rather answer it properly.
The design target is over 90 dB across 10 Hz to 10 GHz, rising to over 100 dB in the 1 MHz – 10 GHz band. Achieved performance is verified per installation, and the verification report is part of the handover documentation.
Yes. The main and secondary chamber dimensions given are the standard configuration; chambers are built to the equipment envelope and the test standard you are working to. Modular expansion lets a facility scale later.
It can be. The shelter integrates network and spectrum analysers, signal generators, power meters, oscilloscopes and environmental monitoring, with automated test sequences and network-based remote control from an external laboratory. Tell us which standards you test to and we will scope the instrumentation against them.
Dedicated precision HVAC with independent backup holds ±2 °C and 45–55% RH, with continuous logging and alarms. Pneumatic isolators handle sub-1 Hz vibration and the acoustic environment stays under 50 dB(A).
Our plants are at Gut No. 243/1B, Pimpalnare, Dindori, Nashik, Maharashtra – 422004. We build there and deliver pan-India.
Send us the drawing.
A tender number, a specification or a drawing set — we will confirm what we can build and by when, within two working days.