Single-Leaf Exit Door — Emergency Exit Doors

Fire Safety Solutions

Emergency Exit Doors

The door people leave through. Outward-opening, self-closing, operable in one push by someone who has never used it before.

At a glance

Service information

The one door that has to open first time.

An escape door is used once, by people who are not thinking clearly, in the dark. Everything about it is designed for that moment: it swings in the direction of travel, it releases with a single push anywhere along the bar, it self-closes behind them, and it is marked so it can be found without reading.

We manufacture the set — leaf, frame, panic or push-bar hardware, self-closing device and signage — and install it so the release actually works against the frame it was made for.

  • Panic / Push-Bar Hardware
  • Outward Opening
  • Self-Closing
  • Signage Included
Public Concourse Exit Doors — Emergency Exit Doors
Public Concourse Exit Doors

What we make

What we manufacture and deliver.

Any one of these can be contracted on its own, or the whole interior delivered under a single award against one drawing set and one schedule. Everything listed is manufactured, supplied and installed by us — not sub-let after award.

  • Exit Door Sets

    Single and double-leaf sets, supplied complete rather than as a leaf on its own.

    • Single and double-leaf emergency exit door sets.
  • Panic & Access Hardware

    Panic bars, push pads and the devices that control entry from outside.

    • Panic bars, push pads and outside access devices.
  • Closers & Hold-Open

    Self-closing devices, and hold-open arrangements where they are permitted.

    • Self-closing devices and hold-open arrangements where permitted.
  • Frames & Escape Direction

    Frames configured to open outward, in the direction of escape.

    • Frames configured for outward opening in the direction of escape.
  • Signage & Markings

    Escape route signage, photoluminescent markings and the hardware schedule.

    • Escape route signage, photoluminescent markings and hardware schedules.
  • Vision Panels & Glazing

    Where the escape route needs to be seen through before it is used.

    • Vision panels and glazing where the escape route needs them.
Double-Leaf Corridor Exit

Standards & compliance

Built to the standards this work is inspected against.

Wording here is deliberate: we design and manufacture to these criteria.

  • Escape provision Opening direction, widths and hardware planned against National Building Code of India Part 4 means-of-escape requirements.
  • Construction Leaves and frames built to the construction requirements set out in IS 3614 for the leaf type specified.
  • Hardware Panic and emergency exit devices selected so the door releases with a single action from the escape side.
  • Certification Test certification is confirmed per contract before supply. Ask us for the current certification position on any door set or system you intend to specify — we will give you a straight answer rather than a brochure claim.
Overhead Door Closer — Emergency Exit Doors
Overhead Door Closer

Certificates held

Not what we design to — what we are audited for.

The certificates from our register that apply to this work, each with its issuing body and certificate number. Nothing here is a claim we have not been audited for.

Certificates held Not what we design to — what we are audited and licensed for, with the certificate number on each.

  • ISO 9001 Quality management BSCIC Certifications Pvt. Ltd. · BN22475/21523 Rev.01
  • ISO 45001 Occupational health & safety
  • ISO 14001 Environmental management
  • ZED Gold Zero Defect Zero Effect — Gold Ministry of MSME · assessed by Conformity India International Pvt. Ltd. · 14072025_402233
All 20 certificates, with issuing bodies and validity dates

Why Finex

Why departments place this work with us.

  • 01

    Doors and systems from one organisation

    The door sets, the detection, the suppression and the civil work around them can run on one order — so nobody is waiting on another trade to finish before they can start.

  • 02

    Made in our own plants

    More than 1,00,000 sq. ft. across two units near Nashik. Frames, leaves and finishing stay under our control rather than being sub-let after award.

  • 03

    Fitted, not just delivered

    A fire door only performs as an installed door set — frame, leaf, ironmongery and seals together. We install and hand over rather than dropping leaves on site.

  • 04

    Straight answers on compliance

    We will tell you exactly what is certified and what is not before you specify it. An awkward conversation early is cheaper than a rejected inspection.

FAQ

Questions we get on this scope.

If yours is not here, ask — we would rather answer it properly.

In the direction of escape — outward, away from the people using it. We configure the frame and hardware for that, and will flag it if a drawing shows otherwise.

Both release the door with one action. A panic bar spans the leaf so it works wherever a person hits it, which suits public buildings; a push pad is a smaller device for openings used by staff who know the building.

Yes. Escape signage and photoluminescent marking are part of the scope, so the route is marked rather than left to a separate order.

They can, provided the escape function is never defeated — the door must still release with a single action from the inside. We will say so plainly if a proposed arrangement compromises that.

Yes. We manufacture near Nashik and install and hand over anywhere in the country.

Send us the drawing.

A tender number, a specification or a drawing set — we will confirm what we can build and by when, within two working days.

Call Now WhatsApp